Abstract:To research the contamination status and distributive regulation of Legionella pneumophila in samples from spring water and analyze the main serotypes and genotypes of the pathogen, a stratified sampling method was adopted to collect water samples randomly from water tank, hot spring pool, shower room of hot spring recreations. Suspected strains were isolated from condensed water samples. Serum agglutination assay and real-time PCR technology were used to identify L. pneumophila. Pulsed-field gel electrophoresis (PFGE) and sequence-based typing (SBT) were used to describe the genetic polymorphism of the isolates. Overall, 53.85% of water samples showed Legionella-positive, and their concentrations ranged from 20 CFU/100 mL to 16 000 CFU/100 mL. The main serotypes were LP1 type and LP3 type and all strains carried dot gene. Among them, 40 isolates were analyzed by PFGE by which 10 distinct patterns were differentiated. They were also selected for SBT analysis and divided into 13 different sequence types in 3 main clonal groups belonging to one homomorphic type. Our results demonstrated high prevalence and genetic polymorphism of Legionella in hot spring recreations of Wenzhou. Hot spring area posed a potential threat to tourists. Spring water of these places should be intervened to prevent occurrence of Legionnaires? disease.
章乐怡, 李毅, 上官智慧, 吴跃进, 谢爱蓉, 王良怀, 陈文斌. 温泉水中嗜肺军团菌污染调查及分子分型研究[J]. 中国人兽共患病学报, 2016, 32(12): 1096-1101.
ZHANG Le-yi, Li Yi, SHANGGUAN Zhi-hui, WU Yue-jin, XIE Ai-rong, WANG Liang-huai, CHEN Wen-bin. Contamination status and molecular typing of Legionella pneumophila in spring environments. Chinese Journal of Zoonoses, 2016, 32(12): 1096-1101.
[1] Blatt SP, Parkinson MD, Pace E, et al. Nosocomial legionnaires? disease: aspiration as a primary mode of disease acquisition[J]. Am J Med, 1993, 95(1): 16-22. doi:10.1016/0002-9343(93)90227-G [2] Ma XY, Wang YQ, Peng XM, et al. Investigation of an legionnaires? disease outbreak associated with contaminated air - conditioning system[J]. Chin J Epidemiol, 1998, 19(4): 200-205. doi:10.3760/j.issn:0254-6450.1998.04.002 (in Chinese) 马小燕,王玉琴,彭晓旻,等. 一起空调系统导致上呼吸道感染样军团病暴发的调查[J]. 中华流行病学杂志,1998,19(4):200-205. [3] Deng CY, Fang XS, Wang CQ, et al. Investigation on an outbreak of Legionnaires?disease caused by Lboz in a suburb of Beijing[J]. Chin J Epidemiol, 2001, 22(3): 182-183. (in Chinese) 邓长英,房兴胜,万超群,等.北京郊区某新兵训练营地发生一起博杰曼军团菌病暴发[J].中华流行病学杂志,2001,22(3):182-183. [4] Ning ZQ, Wang BL, Liu XF, et a. Investigation of an legionnaires? disease outbreak[J].Chin J Public Health, 2004, 20(7): 859. (in Chinese) 宁召起, 王宝兰, 刘晓峰, 等.一起军团菌病暴发调查报告[J]. 中国公共卫生, 2004, 20(7):859. [5] Joseph CA, Ricketts KD. Legionnaires?disease in Europe 2007-2008[J]. Euro Surveill, 2010, 15(21):19493. [6] Yabuuchi E, Agata K. An outbreak of Legionellosis in a new facility of Hot Spring Bath in Hiuga city[J]. Kansenshogaku Zassh, 2004, 78(2): 90-98. [7] Li SX, Chen XP. Investigation on contamination of Legionella pneumophila in recycled water from central air conditioning systems and shower water in large hotels of an urban district in Beijing[J]. J Envir Hyg, 2014, 4(3): 226-230. (in Chinese) 李嵩雪, 陈西平. 北京某城区大型酒店集中空调循环水及淋浴水嗜肺军团菌污染调查[J]. 环境卫生学杂志,2014,4(3):226-230. [8] Liu WY, Si GJ, Xu SS, et al. Characteristics of Legionella pollution of central air conditioning ventilation systems in some public places of Hangzhou,2013-2014[J]. J Environ Occup Med, 2016, 33(2): 163-166. (in Chinese) 刘卫艳,斯国静,徐珊珊,等.2013—2014年杭州市公共场所集中空调军团菌污染特征[J].环境与职业医学,2016,33(2):163-166. [9] Shen L, Xie XH. Report of Legionella pneumophila contamination on shower head of hotel bathroom[J]. Occup Health, 2013, 29(12): 1485-1486. (in Chinese) 沈莉,谢晓红.酒店浴室花洒头上检出嗜肺军团菌的报告[J].职业与健康, 2013, 29(12): 1485-1486. [10] Qin T, Yan G, Ren H, et al. High prevalence, genetic diversity and intracellular growth ability of Legionella in hot spring environments[J]. PLoS One, 2013, 8(3):e59018. doi:10.1371/journal.pone.0059018 [11] Ministry of Health of the People?s Republic of China.WS 394-2012 Hygienic specification of central air conditioning ventilation system in public buildings[S].Beijing:Standards Press of China,2012.(in Chinese) 中华人民共和国卫生部.WS 394-2012 公共场所集中空调通风系统卫生规范[S].北京: 中国标准出版社, 2012. [12] Mahbubani MH, Bej AK,Miller R, et al. Detection of Legionella with polymerase chain reaction and gene probe methods[J]. Mol Cell Probes, 1990, 4: 175-187 doi:10.1016/0890-8508(90)90051-Z [13] Diederen BM,de Jong CM,Kluytmans JA, et al. Detection and quantification of Legionella pneumophila DNA in serum: case reports and review of the literature[J]. J Med Microbiol, 2006, 55(5): 639-642. doi:10.1099/jmm.0.46453-0 [14] Yáñez MA, Carrasco-Serrano C, Barberá VM, et al. Quantitative detection of Legionella pneumophila in water samples by immunomagnetic purification and Real-Time PCR amplification of the dotA Gene[J]. Appl Environ Microbiol, 2005, 71(7): 3433-3441. doi:10.1128/AEM.71.7.3433-3441.2005 [15] Zhou HJ, Ren HY, Zhu BQ, et al. Optimization of pulsed-field gel electrophoresis for Legionella pneumophila subtyping[J]. Appl Environ Microbiol, 2010, 76(5), 1334-1340. doi:10.1128/AEM.01455-09 [16] Dice LR. Measures of the amount of ecgical association between species[J]. Ecology, 1945, 26: 297-302. [17] Sikora A, Wójtowicz-Bobin M, Kozioł-Montewka M, et al. Prevalence of Legionella pneumophila in water distribution systems in hospitals and public buildings of the Lublin region of eastern Poland[J]. Ann Agric Environ Med, 2015, 22(2): 195-201. doi:10.5604/12321966.1152064 [18] Matuszewska R, Krogulska B. Problem wystepowania pałeczek Legionella w instalacjach i urzadzeniach wytwarzajacych aerozol wodno-powietrzny w obiektach słuzby zdrowia[J]. Nowa Med, 2009, 1: 56-60 [19] Bartram J, Yves CH, Lee JV, et al. Legionella and prevention of legionellosis [J]. World Health Ogranization, 2007,193:101-102. [20] Matuszewska R, Krogulska B. Wystepowanie bakterii z rodzaju Legionella w systemach wody chłodniczej[J]. Roczn PZH, 2008; 59(4): 445-454. [21] People?s Republic of China National Tourism Administration. LB/T 016-2011 Classification & Accreditation for service-rated Hot Spring Enterprise[S]. Beijing: Standards Press of China, 2011.(in Chinese) 中华人民共和国国家旅游局. LB/T 016-2011温泉企业服务质量等级划分与评定[S].北京: 中国标准出版社, 2011. [22] Mouchtouri V, Velonakis E, Tsakalof A, et al. Risk factors for contamination of hotel water distribution systems by Legionella species[J]. Appl Environ Microbiol, 2007, 73(5): 1489-1492. doi:10.1128/AEM.02191-06 [23] Buse HY, Schoen Mary E, Ashbolt NJ, et al. Legionella in engineered systems and use of quantitative microbial risk assessment to predict exposure[J]. Water Res, 2012, 46(4): 921-933. doi:10.1016/j.watres.2011.12.022 [24] Zhang LY, Li Y, Zheng WL, et al. Sequence-based typing of Legionella pneumophila isolates from the public cooling tower water[J]. Chin J Zoonoses, 2013, 29(3): 262-266, 273. (in Chinese) 章乐怡, 李毅 ,郑文力, 等.公共场所冷却塔水嗜肺军团菌的基因序列分型研究[J].中国人兽共患病学报,2013, 29(3):262-266,273.